About Services
   

PULSER

 

Model DS200 - Double Metal Sheet Detector

Features
  • Pulsed Electromagnetic
    does not hold on to metal blank or sheet
  • Single metal thickness ranges
    .25 mm to 6.0 mm (.01 “ to .240”)
  • Four Probe Diameters
    36mm, 42mm, 54mm, 75mm
    SELECT
  • Metal Present Output
    transistor (PnP) output when metal present
  • Proximity Detector
    built in proximity probe to detect metal, last sheet
  • Push-Button Calibration
    instantaneously measure thickness, calculates reject threshold
  • Teach
    with a single sample or two sample,
  • Fast Response to Double Detection
  • Diagnostic Warning
    alternately flashing lights for error and probe failure, fail safe output
  • Power Input
    Range 100 to 240 VAC @ 50-60 Hz 20 w
    Quick Connect
    terminals for fast replacement and to reduce downtime
  • Contact Relay output rated at 10 AMPS (½ HP) @240VAC, 8 AMPS @24 VDC.
  • Works with all Prime PE Model probes

SPECIFICATIONS

Model DS200

 

PE42 Side and Face
Model PE42
Prime’s Model DS200 Single Probe Double Metal Sheet Detector is installed in difficult locations where sensing is only possible on one side. It detects ferrous metals over a thickness range of .25 mm to 6.0 mm (.01” to .240” ). The DS200 measures the change in it’s magnetic field as metal is in contact with it's face. A new sensing element in the probe head increases sensitivity and improves stability compared to other brands. To calibrate, simply insert a sheet in front of the probe and push the calibrate button. The detector automatically sets the reject threshold above the single sheet reading. It’s form “C” contact relay de-energizes if a double is detected, power is lost or a probe failure is detected. One additional PNP transistor output turns on when metal is detected. This metal output is applied (including doubles) to a good sheet counter, jam detector or last sheet detect circuit. The Model DS200 detector has fault detection that immediately analyzes any problem and operates a blinking Green LED code that directs the operator or maintenance department to the problem.
Specifications:

Power input:

Ranges from 100 Volts to 240 Volts AC Max, 50 to 60 Hz, at 20 Watts

Output Response < 140 mSec. w/PE36 to <250mSec w/PE75
Outputs: SPDT contact relay Double detected, NC closed Max. load 10 Amps @ 240 Vac, 8 Amps @ 24 V dc ½ HP @ 240 V ac
Metal Present Output:

PNP transistor, sourcing 24 Volts dc, 100mA max.
Metal detected= 24 V dc,
No metal = 0 V dc

Output fail Safe: Contact goes to double condition. Metal Present output turns off, indicating no metal present.
Metal Sensitivity: Ferrous metal, steel, tinplate
Calibration: Push-button switch with single sheet or two sample teach for fine accuracy
Sample Indicators: Green for single, amber for double, green blinking probe is bad or disconnected
External inputs: Calibrate & output latched reset
Sensor Operation: magnetic flux field generated by a quick electromagnetic pulse is shunted across sensor poles by the thickness of metal. Maximum thickness is limited by the diameter of the probe. The chart below provides a range for each probe.
Probe Model
Probe Diameter

Breakaway Force

Min. Thickness
Max. Thickness
PE36
36mm (1.42")
<1 lb.
0.25mm (.01")
2.3mm (0.09")
PE42
42mm (1.65")
<1 lb.
0.25mm (.01")
3.6mm (0.14")
PE54
54mm (2.13")
<1 lb.
0.25mm (.01")
4.6mm (0.18")
PE75
75mm (2.95)
<1 lb.
0.25mm (.01")
6.0mm (0.24")

 


 




Additional Product Information
PROBE SELECT
SPECIFICATIONS
WIRING
SALES FLYER