Model
DS160
Single
Probe - Double Metal Sheet Detector
for nonferrous metal
PRIME’S …
Model
DS160 Double Metal Sheet Detector
comprises a control module in
a sheet metal housing with one
probe to form a system that detects
the thickness of nonferrous metals
in front of the probe. The detector
system may be used on automatic
sheet feeders where double or
overlapping sheet material may
jam or damage the receiving machine.
A double feed produces an output
to stop the machine or signal
the operator.
Features:
- Non-contact
detection to 25-mm from
metal
- Fast
and easy pushbutton teach calibration
- Push
calibration button once
to setup double sheet
detection
- Select
95 to 130 or 200 to 250
volt operation through
internal jumpers.
- Automatic
setup of system gain and
operating parameters
- LED
indicators report the
gage states of NO DOUBLE
and DOUBLE
- Removable
terminal blocks for quick
change out of the control
module.
|


|
- Sensitive
to thin aluminum foil,
300 series stainless,
copper plated circuits,
and other metals
- Push
calibration button twice
to detect a variation
less than a double thickness
- Form
C relay output providing
normally open or normally
closed contacts.
- Nonvolatile
memory that retains all
calibration parameters
even when power is removed.
- Optional
latching relay output
that is cleared by asserting
the CAL/RES input or remote
calibration input.
|
Power
input: |
Configurable
120 Volts Max or 240 Volts AC
Max, 50 to 60 Hz, 300 mA operating
load |
| Output
Response |
<
10 mSec. |
| Outputs: |
SPDT
contact relay Double detected,
NC closed Max. load 10 Amps @ 240
V ac, 8 Amps @ 24 V dc ½ HP @ 240
V ac |
| Output
fail Safe: |
Contact
goes to double condition. PNP changes
to nothing condition. Flashing indicators
sequence code identify problems. |
| Metal
Sensitivity: |
Non-ferrous
metal, Aluminum foil, less than
.05-mm (.002"),
300
Series Stainless steel, less than.4-mm
(100"),
Copper thickness range: less than 2 ounce
printed circuit |
| Calibration: |
Push-button
switch located on front panel or
terminals for external connect |
| Sample
Indicators: |
Green
for single, amber for double, green
blinking probe is bad or disconnected |
| External
inputs: |
Configure for Calibrate or Output
latched reset |
| Sensor
Operation: |
Eddy
current sensitive |
|
|
| Additional
Product Information
|
|
|
|
|