About Services
Applications

Model DS150

Dual Probe, Double Metal Sheet Detector

Features:

Push-button calibration, instantaneously sets reject threshold and adjusts signal for type and thickness of metal detected.

•Multi-gauge double detection without calibration changes.

•Thickness Detection range of .05 mm to 8 mm (.002” to .300”) provides flexibility for a broad range of thickness applications and metals.

•Diagnostic warning is provided through various indicator flash patterns for error and probe failure.

•Power Input is user configured to 120 Volts AC or 240 Volts AC @ 50-60 Hz.

•Wide trans./rec. probe separation to 75 mm (3”) when used with P70CS on light gauge steel.

•Quick connect terminals for fast replacement, and to reducing downtime.

•Contact relay output to interface with most input or control circuits, contacts rated at 10 AMPS (½ HP) @ 240 Vac, 8 AMPS @24 VDC.

Metal blanks that are free to bounce or move vertically as much as 75 mm (3 inches) in a conveying system are easily monitored by Prime's Model DS150. It senses many different metals by using separate transmitter and receiver probes that can detect metal within a 3” (75 mm) range. It inspects over a thickness range of 002” to .320, (.05 mm to 8 mm). Calibration is completed by pressing a push-button located on the front cover with a nominal and double sample. It immediately senses several conditions and sets the double reject threshold. If it detects any system failures, while operating, it begins flashing one of its indicators and switches its output to reject. The DS150 is an excellent detector for steel, aluminum, tinplate, thick *stainless steel, copper, brass and many other metals.

* thin stainless, copper and aluminum film may require a Model DS3410

Model DS150

Model P70A

Model P1000B


Model P70CS

two required

 

 

 

Specifications:

Power input:

Configurable 120 Volts Max or 240 Volts AC Max, 50 to 60 Hz, 300 mA operating load

Output Response < 10 mSec.
Outputs: SPDT contact relay Double detected, NC closed Max. load 10 Amps @ 240 V ac, 8 Amps @
Output fail Safe: Contact goes to double condition. Flashing indicators sequence code identify problems.
Metal Sensitivity:

Ferrous metal, steel, tinplate Thickness range: 04 mm to 8 mm (.002” to .300”) Nonferrous metal up to 16 mm or .600" Al. (except: less than .05 mm thin Copper, less than 1 mm Nonmagnetic Stainless Steel must use Model DS3400)

Calibration: Push-button teach Two measurements required. Nominal and double thickness
Sample Indicators: Green for single, amber for double, green blinking probe is bad or disconnected
External inputs: Output latched reset. No external calibrate on this unit. See DS1500
Sensor Operation: Eddy currents impede transmitted signal to receiver proportional to the metal thickness.

 

 

 

 

 

 

 

 

 

 