| Single
Probe - Double Metal
Sheet Detector |
Features
- Thickness
range .05 mm to 1.5 mm (.002 “ to .060”)
provides flexibility for a broad range
of thickness applications and metals.
- Push-button
calibration instantaneously sets reject
threshold and adjusts signal for metal
- Can
calibrate with a single sample, then
automatically determine the double value
- Also
can calibrate with two sample for best
resolution
- Once
calibration is initiated, wait for metal
present
- External
calibrate capable
- Quick
response to double in 3 mS to 21 mS •
Automatic Setup identifies probe type
and selects the reject level for metal
- Diagnostic
warning alternately blinking lights for
error and probe failure, fail safe output
- Power
Input configures to 120 or 240 VAC @ 50-60
Hz for international application
- Quick
connect terminals for fast replacement
and to reduce downtime
- Contact
relay output rated at 10 AMPS (½ HP) @240VAC,
8 AMPS @24 VDC.
- Optional
latch or automatic output reset
- Works
with all Prime PM Model probes
|
 |
|
Model
DS100
|
 |
|
Model
PM11
|
|
| Prime’s
Model DS100 Single Probe Double Metal Sheet
Detector is installed in difficult locations
where sensing is only possible on one side.
It detects ferrous metals over a thickness
range of .05 mm to 1.5 mm (.002” to .060”
). The DS100 measures the change in it’s magnetic
field as metal passes near it’s face. A new
sensing element in the probe head increases
sensitivity and improves stability compared
to other brands. To calibrate, simply insert
a sheet in front of the probe and push the
calibrate button. The detector automatically
sets the reject threshold above the single
sheet reading. It’s
form “C” contact relay de-energizes if a double
is detected, power is lost or a probe failure
is detected. One additional PNP transistor
output turns on when each single is detected.
This single output is applied to a good sheet
counter, jam detector or last sheet detect
circuit. The Model DS100 detector has fault
detection that immediately analyzes any problem
and operates a blinking Green LED code that
directs the operator or maintenance department
to the problem. |
|
Power
input:
|
Configurable
120 Volts Max or 240 Volts AC Max, 50 to
60 Hz, 300 mA operating load
|
| Output
Response |
<
10 mSec. |
| Outputs: |
SPDT
contact relay Double detected, NC closed
Max. load 10 Amps @ 240 Vac, 8 Amps @ 24 V
dc ½ HP @ 240 V ac |
| Single
Present Output: |
PNP transistor Nothing detected single = 24
V dc nothing = 0 V dc load source 24 Volts,
100mA max. |
| Output
fail Safe: |
Contact
goes to double condition. PNP changes to nothing
condition. Flashing indicators sequence code
identify problems. |
| Metal
Sensitivity: |
Ferrous
metal, steel, tinplate Thickness range: 04
mm to 1.5 mm (.002” to .060”) |
| Calibration: |
Push-button
switch with single sheet |
| Sample
Indicators: |
Green
for single, amber for double, green blinking
probe is bad or disconnected |
| External
inputs: |
Calibrate & output latched reset |
| Sensor
Operation: |
Permanent
magnetic flux field is shunted across sensor
poles by the thickness of metal. Maximum thickness
is limited by the diameter of the probe. The
chart below provides a range for each probe. |
|
Probe
Model
|
Probe
Diameter
|
Breakaway
Force
|
Min.
Thickness
|
Max.
Thickness
|
| PM4 |
18 mm (.7")
|
13 lb. |
.04 mm (.0015")
|
.4 mm (.015")
|
| PM10 |
30 mm (1.18")
|
20 lb. |
.1 mm (.004")
|
1.0 mm (.040")
|
| PM15 |
36 mm (1.85")
|
30
lb. |
.15 mm (.006")
|
1.5 mm (.060")
|

|
|
| Additional
Product Information
|
|
Probes
|
|
up
to .5mm
|
|
|
up
to 1mm
|
|
|
up