MODEL
SD203
DUAL
CHANNEL MISSING TAB DETECTOR
Features...
- Push-button
calibration
optimizes settings and reduces time
to set up.
- Microprocessor
control provides better measuring
resolution and reliability.
- Aluminum
& Steel sensitivity eliminates
the need to stock more than one model.
- Two
detectors in one chassis provides
a compact package and requires less
panel space.
- Two
digital displays to monitor relative
thickness, signal strength and fault
conditions.
- Diagnostic
messages quickly isolate errors
and failures in the detector and probes.
- Operating
Power is standard 24 Volts DC.
- Six
solid state transistor outputs
for comprehensive control of Single.
Double, No Tab, Tab & Channel Fault
detection.
- Quick
disconnect terminals decrease replacement
downtime.
|

- Functionally
compatible with early Prime &
Hyde Park Models DS33, DS35, DS37,and
DS38 and will fit in the same panel
footprint.
- Optional
communication port expands information
to external systems.
|
|
.
The New Model SD203 and its push-to-calibrate
feature provides a simple and dependable
way to begin monitoring can ends traveling
through a conversion press. The Model
SD203 is two detectors in one for use
on each lane of a conversion press.
This Double or Nothing detector along
with two sets of probes installed at
the discharge of each lane detects a
missing tab. Each channel has three
solid-state outputs. The three outputs
energize for tab present, no tab and
a detected fault (for example inoperative
probe)
Calibrating
the detector is simple. Just push the
Calibrate push button for either channel
after inserting an end with a tab between
the transmitter and receiver probes.
The Model SD203 will automatically measure
and memorize the tab. Future ends missing
a tab cause the No Tab output to turn-on.
Calibration is that easy. All outputs
are solid state transistor type and
are configured with a jumper to sink
or source current. There are no additional
adjustments or fine tuning. Dual two-digit
LED displays indicate probe signal strength
or fault codes. Quick disconnect terminals
provide fast and easy changeover . Operating
power requirement for the Model SD203
is 24 volts @ 200 milliamperes DC. .
|
|
Specifications:
-
Power
Input: (required), Voltage: 24
V DC *10 % ripple Current: >350 mA.
- Logic
Inputs external designated
Calibration and Auxiliary
1 & 2. Hardware consists of jumper
selected transistor type : pull-up
mode for source drivers, pull down
for sinking drivers. (AUX. changes
frequency to steel or aluminum optimum
sensitivity)
- Logic
Impedance is 4.7K ohms, response
to less than 1 m Sec.
- Switching
thresholds: above 6.4V when going
high, below 5 volts when going low.
- Probe
Inputs tuned for Prime transmitter
and receivers only for each channel.
- Outputs
(6) Transistor types, designated Single,
Double, Tab, No-Tab, 2-Fault Jumper
select current sinking or source Source
current limit at 160 mA, combined
outputs. Source voltage: 22 Volts
Sinking current: 100 mA Max. Sinking
voltage: 30 Volts Max.
- Probe
Types AY, AV, AZA, CB, CFB and
all in P15 family for optimal operation,
also works with AK, AVB, CA, CF and
P70 family but not optimized for best
operation.*
- Response
Time 1 to 16 m Sec (Effected by
the metal type and the thickness during
calibration).
- Thickness
Range 1 mm (.040") with P15CS,
Varies with probe and separation.
|

- Probe
Separation max
75 mm with P15CS.
- Max
range not advisable when trying
to detect pull tab. For pull tab detection
use any of the probe types recommended
under Probe Types with 16 mm
(.625") separation. Do not use
probes ending with S.
- Reject
threshold. Factory set to 50%
ON and 30% OFF of calibrated nominal.
- Displays
Two channel, two digit alphanumeric
LED display. During operation indicates
signal strength and fault location.
During calibration nominal value or
calibration fault.
- Indicator
Lamps consist of two channels
of green for present and red for over
or under nominal value. Also flash
for faults.
|
|
|
| Additional