Model
SD202
SMART
DUAL
CHANNEL DOUBLE & MISSING END DETECTOR
"Great
for Double end detection after end press
and curler"
|
|
Features...
- Push-button
calibration
optimizes settings and reduces time
to set up.
- Microprocessor
control provides better measuring
resolution and reliability.
- Aluminum
& Steel sensitivity eliminates
the need to stock more than one model.
- Two
detectors in one chassis provides
a compact package and requires less
panel space.
- Two
digital displays to monitor relative
thickness, signal strength and fault
conditions.
- Diagnostic
messages quickly isolate errors
and failures in the detector and probes.
- Operating
Power is standard 24 Volts DC.
- Six
solid state transistor outputs
for comprehensive control of Single.
Double, No Tab, Tab & Channel Fault
detection.
- Quick
disconnect terminals decrease replacement
downtime.
- Functionally
compatible with early Prime &
Hyde Park Models DS33, DS35, DS37,and
DS38 and will fit in the same panel
footprint.
- Optional
communication port expands information
to external systems.
|

|
|
Fast!
Prime’s versatile Model SD202 is fast
enough to sense double ends in a conversion
press or in the high velocity of a rotating
curler. This dual channel, multifunctional
detector is also used to monitor sheets
entering a strip feed press and at the
same time watch for single ends exiting
after each stroke. Any end or sheet
between the probes for .003 seconds
or longer is inspected. Beverage aluminum
202 ends traveling at 25 ft/second (150
ends/second) is inspected. Food 303
ends are detected even easier. The Model
SD202 holds the output for a minimum
of 25 milliseconds to allow a PLC time
to recognize the double or to allow
a latching relay to respond. The Model
SD202 is two detectors in one package.
You can use the detector on two different
lines or monitor two positions on the
same line. It is easy to calibrate.
Just press a push-button on the front
of the detector, with a single end between
the probes. It’s that easy. Two alphanumeric
displays provide information on signal
strength, calibration and detected faults.
Pinpointing a system defect is easy
with the Model SD202.
|

|
Each channel has jumper changeable
current sink or current source
outputs for Double,Single and
Fault warnings that can interface
directly with most PLC-DC inputs.
|
|
|
Specifications:
- Power Input: (required),
Voltage: 24 V DC *10 % ripple Current:
>350 mA.
- Logic Inputs external designated
Calibration and Auxiliary
1 & 2. Hardware consists of jumper
selected transistor type : pull-up
mode for source drivers, pull down
for sinking drivers. (AUX. changes
frequency to steel or aluminum optimum
sensitivity)
- Logic Impedance is 4.7K ohms,
response to less than 1 m Sec.
- Switching thresholds: above
6.4V when going high, below 5 volts
when going low.
- Probe Inputs tuned for Prime
transmitter and receivers only for
each channel.
- Outputs (6) Transistor types,
designated Single, Double, Tab,
No-Tab, 2-Fault Jumper select
current sinking or source Source current
limit at 160 mA, combined outputs.
Source voltage: 22 Volts Sinking current:
100 mA Max. Sinking voltage: 30 Volts
Max.
- Probe Types AY, AV, AZA,
CB, CFB and all in P15 family for
optimal operation, also works with
AK, AVB, CA, CF and P70 family but
not optimized for best operation.*
- Response Time 1 to 16 m Sec
(Effected by the metal type and the
thickness during calibration).
- Thickness Range 1 mm (.040")
with P15CS, Varies with probe and
separation.
- Probe Separation max 75 mm
with P15CS.
- Max range not advisable when
trying to detect pull tab. For pull
tab detection use any of the probe
types recommended under Probe Types
with 16 mm (.625") separation.
Do not use probes ending with S.
- Reject threshold. Factory
set to 50% ON and 30% OFF of calibrated
nominal.
- Displays Two channel, two
digit alphanumeric LED display. During
operation indicates signal strength
and fault location. During calibration
nominal value or calibration fault.
- Indicator Lamps consist of
two channels of green for present
and red for over or under nominal
value. Also flash for faults.
|
|
|