MODEL
SD200
"DOUBLE
SHELL & MISSING TAB DETECTOR"
"Great
for a stay-on-tab conversion press"
|
|
Featuring...
- Push-button
calibration
optimizes settings and reduces time
to set up.
- Microprocessor
control provides better measuring
resolution and reliability.
- Aluminum
& Steel sensitivity eliminates
the need to stock more than one model.
- Two
detectors in one chassis provides
a compact package and requires less
panel space.
- Two
digital displays to monitor relative
thickness, signal strength and fault
conditions.
- Diagnostic
messages quickly isolate errors
and failures in the detector and probes.
- Operating
Power is standard 24 Volts DC.
- Six
solid state transistor outputs
for comprehensive control of Single.
Double, No Tab, Tab & Channel Fault
detection.
- Quick
disconnect terminals decrease replacement
downtime
- Functionally
compatible with early Prime &
Hyde Park Models DS33, DS35, DS37,and
DS38 and will fit in the same panel
footprint.
|
Need
two Shell Detectors? Consider SD202
Need
two Tab Detectors? Consider
SD203

|
| At the
touch of a fingertip, the New Model SD200
and its push-to-calibrate feature, provides
a simple and dependable way to begin monitoring
can ends traveling through your conversion
press. The Model SD200 is two detectors
in one for use on each lane of a conversion
press. This Double or Nothing detector,
along with two sets of probes installed
at the infeed and discharge of each lane,
will detect a double shell and missing
tab. Each channel has three solid-state
outputs. The three Infeed (shell) outputs
energize for single, double and fault
conditions. The three Discharge (tab)
outputs energize for tab present, no tab
and fault conditions.
Calibrating
the detector for your application is
simply done by pushing either of the
Calibrate push buttons on the front
of the detector. To calibrate, you insert
a single shell between the probes and
push the button on the Infeed channel.
It will automatically set the threshold
levels for passing singles and rejecting
doubles. Then, you insert an end with
a tab between its probes and push the
button on the discharge channel. It
will automatically set the level for
tabs and reject a shell missing a tab.
Calibration is completed that easily.
The detector is ready to protect expensive
conversion tooling. There are no additional
adjustments or fine tuning. It will
automatically optimize itself, if possible,
to function in the application. Dual
two-digit LED displays report relative
thickness, probe signal strength and
diagnostic fault conditions. The detectors
are housed in one rugged metal chassis.
Quick disconnect terminals will provide
fast and easy changeover. The operating
power requirement for the Model SD200
is standard 24 Volts DC.
|
Specifications:
- Power
Input: (required), Voltage: 24
V DC *10 % ripple Current: >350 mA.
- Logic
Inputs external designated
Calibration and Auxiliary
1 & 2. Hardware consists of jumper
selected transistor type : pull-up
mode for source drivers, pull down
for sinking drivers. (AUX. changes
frequency to steel or aluminum optimum
sensitivity)
- Logic
Impedance is 4.7K ohms, response
to less than 1 m Sec.
- Switching
thresholds: above 6.4V when going
high, below 5 volts when going low.
- Probe
Inputs tuned for Prime transmitter
and receivers only for each channel.
- Outputs
(6) Transistor types, designated Single,
Double, Tab, No-Tab, 2-Fault Jumper
select current sinking or source Source
current limit at 160 mA, combined
outputs. Source voltage: 22 Volts
Sinking current: 100 mA Max. Sinking
voltage: 30 Volts Max.
- Probe
Types AY, AV, AZA, CB, CFB and
all in P15 family for optimal operation,
also works with AK, AVB, CA, CF and
P70 family but not optimized for best
operation.*
- Response
Time 1 to 16 m Sec (Effected by
the metal type and the thickness during
calibration).
- Thickness
Range 1 mm (.040") with P15CS,
Varies with probe and separation.
|

- Probe
Separation max
75 mm with P15CS.
- Max
range not advisable when trying
to detect pull tab. For pull tab detection
use any of the probe types recommended
under Probe Types with 16 mm
(.625") separation. Do not use
probes ending with S.
- Reject
threshold. Factory set to 50%
ON and 30% OFF of calibrated nominal.
- Displays
Two channel, two digit alphanumeric
LED display. During operation indicates
signal strength and fault location.
During calibration nominal value or
calibration fault.
- Indicator
Lamps consist of two channels
of green for present and red for over
or under nominal value. Also flash
for faults.
|
|
|