Model
DS3400
THIN
METAL DETECTOR
"Great
Thickness Monitor for
Copper Circuit Boards,
Nonmagnetic Stainless Steel, >1 mil
Aluminum Foil Packets"
|
|
Features:
- Ultra-sensitive
to very thin nonferrous metals. For
example 1/4 ounce copper, less than
1 mil aluminum
- Pushbutton
Teach Calibration
- Store
up to eight thickness calibrated values
- Automatic
signal strength adjustment and probe
identification at start-up
- Self
diagnostic messages quickly isolate
system problems, errors and failures
- Operating
Power 90 - 240 Volts AC @ 50-60 Hz.
- Compact
Size, (210 mm x 170 mm x 50 mm) to
fit in tight spaces
- Quick
connect terminals for fast replacement
and to reduce downtime
-
Latched
or momentary output
-
Output
relay response less than 10 mS
- Separate
SPDT output relays for Over and Under
- Four
possible logic output combinations
for Over, Under, Nominal and Nothing
|
|
|
The
Model DS3400 is an easy to operate Thin
Metal Thickness Detector. Control outputs
are available for Over, Under, Normal
thickness and Nothing present.
Up
to eight separate thickness values are
stored and recalled later through a
remotely located selector switch module.
Nonferrous metals under .025 mm (.001")
thickness are measurable for variations
Calibration
is simple. Place a metal sheet between
the probe assembly and push the Calibration
button. That's all. It calculates the
double thickness and sets the reject
threshold. The detector sets it’s reject
threshold to 50% between the first and
calculated second thickness.* The display
prompts either OT (over thickness) or
UT (under thickness). As a double metal
detector the Model DS3400 discriminates
single, double, and no-metal conditions.
Nonvolatile memory stores all settings
if power is lost. Its a great value.
The
DS3400 discriminates between .1/2, 1,
& 2 ounce copper. It also detects
4 ounce copper. However this increased
thickness is detectable with most of
our other double metal detectors, including
Prime's general purpose Model
DS150.
*
Go to our Model
DS3410 for applications where the
required detectable thickness difference
is less than double (50% of nominal).
For example: if the detectable difference
is between 1 and 1.5 ounce or .5 to
.8 ounce copper plate. The Model DS3410
has adjustable reject thresholds that
range from 1 to 99% of the nominal thickness.
In addition the DS3410 permits two sample
calibration. Both the nominal and reject
values are manually entered through
the pushbutton teach feature.
|
|
Specifications:
- Power
Input: 100 to 240 VAC, 50/60 Hz
300 mA operating load Output:
2 SPDT contact relays Max load: 10
Amps @ 240 V AC 8 Amps @ 24 V DC ½
HP @ 240 V AC
- Output
Fail-safe: Defaults to reject
w/power off
- Output
Response: adjustable to < .030,
.100, .500, 1 second
- Thickness
Range: .5 to 2 ounce copper plate.
Up to Nonmagnetic Stainless Steel.
(for Magnetic SS see the latest DS1500
family detector)
- Probes:
All probes beginning with P1C, P1CS,
type "AX"
- Probe
Separation: 12 mm to 75 mm (.5
to 3”) or more. Max. varies w/(metal,
thickness & probe, separation). Maximum
range is realized with Model P1CS
transmitter & receiver probes. .
|
- Calibration
Methods: Push-button switch used
to measure thickness between probes
during calibration. Manually place
sample between probes, push Calibration
button.
- Enable
Input: enable output.
- Over
Reject Threshold: 50% between
two sample calibration. Under threshold
via 50% interpolation
- LED
Indicators: Green for single,
Amber for Over, Under & Nothing detected.
- Display
Indication: 2 digit LED, alphanumeric,
.5 inch high. Setup menu, calibration
mode, operating probe signal strength,
fault codes
- Sensor
Operation: Eddy Current in metal
impedes signal from transmitter to
receiver. Impedance changes as metal
thickness changes.
|
|
|
| Additional