Model
DS1520
Multi-Thickness
Detector
"Great
for Frequent Gauge Changes, NOMINAL
Thickness Monitor and Thickness Classification"
|
|
Dual
Probe - Double Metal Sheet Detector
We
call it a Double Metal Sheet Detector
but it is much more.
- Same
as DS1510 with
adjustable OVER, UNDER threshold and
with a Model SM10
Selection Module, it stores
up to 10 separate application values.
- Separate
adjustments for OVER & UNDER
threshold. Adjust reject thresholds
in 1% increments up to 99%.
- Separate
relay outputs for OVER and UNDER rejects
- Optional
Manual or Automatic calibration eliminates
setup time and permits optimized settings
- Self
diagnostic messages quickly isolate
system problems, errors and failures
- Automatic
frequency and gain settings provide
simple, quick and accurate startup
- Operating
Power 90 - 240 Volts AC @ 50-60 Hz.
- Compact
Size, (210 mm x 170 mm x 50 mm) to fit
in tight spaces
- Quick
connect terminals for fast replacement
and to reduce downtime
- Latched
or momentary output option
|
 |
|
Model
DS1520
|
|
|
|
|
|
|
The
Model DS1520 is an easy to operate dual
probe metal thickness detector. Variations
in thickness as small as 1% are detectable.
Control outputs are available for OVER,
UNDER, Normal thickness and NOTHING present.
Up to ten separate thickness values can
be stored and recalled later through a
remotely located selector switch module.
Ferrous and nonferrous metals over a range
of .05 mm to 8 mm (.002” to .300”) may
be monitored with Prime’s sensing probes.
Calibration
is simple. Select a memory switch position.
Place a metal sheet between the probe
assembly and push the calibrate button.
Add another sheet between the assembly
and push the button again. The second
sheet does not have to be the same thickness.
Repeat both steps for up to ten separate
sheet sizes. After calibration, the detector
sets it’s reject threshold to 50% between
the first and second thickness. Even the
50% default reject threshold setting is
manually adjustable by holding the calibrate
button in for 3 seconds. The display prompts
either OT (over thickness) or UT (under
thickness). Releasing and pushing the
button again advances the tolerance value
over a range of 1 to 99%.
As
a double metal detector the Model DS1520
can discriminate single, double, and no-metal
conditions.
As
a coil thickness or weld splice monitor
it can detect under, over (weld), and
nothing present conditions. The detection
system is not considered a precision thickness
measuring device. However, if metal passing
between it probes is vertically confined
to 5 mm (.200"), it is able to detect
a change of .0250 mm out of .254 mm (.001"
out of .010"), .125 out of 2.5 mm
( 005" out of .100") & .4
mm out of 6 mm (015" out of .250).
The
NOMINAL Tracking feature adjusts
for acceptable variations in the nominal
thickness.
No
need to worry about loosing values. Nonvolatile
memory stores all settings if power is
lost. Its a great value.
|
|
Specifications:
- Power
Input: 100 to 240 VAC, 50/60 Hz
300 mA operating load.
- Output:
2 SPDT contact relays Max load: 10 Amps
@ 240 V AC 8 Amps @ 24 V DC ½ HP @ 240
V AC.
- Output
Fail-safe: defaults to reject w/power
off
- Output
Response: adjustable to < .030,
.100, .500, 1 second.
- Probe
Assessment: * determines probe type,
probe separation, nothing present signal
level when powered up or AUXIN input
is closed.
- Thickness
Range: .5 to 2 ounce copper plate.
Up to 100 nonmagnetic stainless steel.
Magnetic SS see DS1500 Family.
- Probe
Models: all probes beginning with
P15, P70, P1000.
- Probe
Separation: 12 mm to 75 mm (.5 to
3”) or more. Max. varies w/(metal, thickness
& probe, separation). Maximum range
is realized with Model P15CS, P70CS,
P1000B.
|
- Calibration:
push-button switch used to change time
interval or manually initiate calibration.
*Two sample calibration. Manually place
two samples between probes, push Cal.
button.
- Enable
Input: enables controlled output
at specific interval.
- Reject
Threshold: variable from 1 to 99%
between two sample calibration. Separate
adjustments for OVER and UNDER.
- LED
Indicators: (1)Green for single,
(3)Amber for OVER, UNDER & NOTHING detected.
- Sensor
Operation: eddy Current in metal
impedes signal from transmitter to receiver.
Impedance changes as metal thickness
changes.
- Display
Indication: 2 digit LED, alphanumeric,
.5 inch high. Setup menu, calibration
mode, operating probe signal strength,
fault codes.
|
|
|
| Additional
Product Information
|
|
|
|
|