AUTOMATIC & PUSHBUTTON TEACH CALIBRATION
DETECT OVER,UNDER, NORMAL AND NOTHING
DIGITAL DISPLAY FOR SENSITIVITY & DIAGNOSTICS REJECT THRESHOLD ADJUSTABLE
GREAT WELD OR SPLICE DETECTOR

Dual Probe - Double Metal Sheet Detector

We call it a Double Metal Sheet Detector but it is much more

  • Separate adjustments for over & under thresholdAdjust reject thresholds in 1% increments up to 99%.
  • Detects Over and Under thickness from Nominal.
  • Separate outputs for Over and Under rejects
  • Outputs indicate Nominal, Over, Under and Nothing present
  • Automatic calibration eliminate setup time and optimize settings
  • Self diagnostic messages quickly isolate system problems, errors and failures
  • Automatic frequency and gain settings provide simple, quick and accurate startup
  • Operating Power 90 - 240 Volts AC @ 50-60 Hz.
  • Compact Size, (210 mm x 170 mm x 50 mm) to fit in tight spaces
  • Quick connect terminals for fast replacement and to reduce downtime
  • Latched or momentary output option

Model DS1510

The bottom probe, of this dual probe assembly, is not shown in this picture.

 

The Model DS1510 is an easy to operate dual probe metal thickness detector. Variations in thickness as small as 1% are detectable. Control outputs are available for Over, Under, Normal thickness and Nothing present. Up to two separate thickness values can be stored and recalled later through a remote switch. Ferrous and nonferrous metals over a range of .05 mm to 8 mm (.002” to .300”) may be monitored with Prime’s sensing probes.

Calibration is simple. Place a metal sheet between the probe assembly and push the calibrate button. Add another sheet between the assembly and push the button again. The second sheet does not have to be the same thickness. Repeat both steps for up to ten separate sheet sizes. After calibration, the detector sets it’s reject threshold to 50% between the first and second thickness. Even the 50% default reject threshold setting is manually adjustable by holding the calibrate button in for 3 seconds.

The display prompts either OT (over thickness) or UT (under thickness). Releasing and pushing the button again advances the tolerance value over a range of 1 to 99%. As a double metal detector the Model DS1510 can discriminate single, double, and no-metal conditions.

As a coil thickness or weld splice monitor it can detect under, over (weld), and nothing present conditions. The detection system is not considered a precision thickness measuring device. However, if metal passing between it probes is vertically confined to 5 mm (.200"), it is able to detect a change of .0250 mm out of .254 mm (.001" out of .010"), .125 out of 2.5 mm ( 005" out of .100") & .4 mm out of 6 mm (015" out of .250).

The Nominal Tracking feature adjusts for acceptable variations in the nominal thickness.

No need to worry about loosing values. Nonvolatile memory stores all settings if power is lost. Its a great value.

Specifications:

  • Power Input: 100 to 240 VAC, 50/60 Hz 300 mA operating load.
  • Output: 2 SPDT contact relays Max load: 10 Amps @ 240 V AC 8 Amps @ 24 V DC ½ HP @ 240 V AC.
  • Output Fail-safe: defaults to reject w/power off
  • Output Response: adjustable to < .030, .100, .500, 1 second.
  • Probe Assessment: * determines probe type, probe separation, nothing present signal level when powered up or AUXIN input is closed.
  • Thickness Range: .5 to 2 ounce copper plate. Up to 100 nonmagnetic stainless steel. Magnetic SS see DS1500 Family.
  • Probe Models: all probes beginning with P15, P70, P1000.
  • Probe Separation: 12 mm to 75 mm (.5 to 3”) or more. Max. varies w/(metal, thickness & probe, separation). Maximum range is realized with Model P15CS, P70CS, P1000B.

 

  • Calibration: push-button switch used to change time interval or manually initiate calibration. *Two sample calibration. Manually place two samples between probes, push Cal. button.
  • Enable Input: enables controlled output at specific interval.
  • Reject Threshold: variable from 1 to 99% between two sample calibration. Separate adjustments for Over and Under.
  • LED Indicators: (1)Green for single, (3)Amber for Over, Under & Nothing detected.
  • Sensor Operation: eddy Current in metal impedes signal from transmitter to receiver. Impedance changes as metal thickness changes.
  • Display Indication: 2 digit LED, alphanumeric, .5 inch high. Setup menu, calibration mode, operating probe signal strength, fault codes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 