Model
DS1510
AUTOMATIC & PUSHBUTTON TEACH CALIBRATION
DETECT OVER,UNDER, NORMAL AND NOTHING
DIGITAL DISPLAY FOR SENSITIVITY & DIAGNOSTICS REJECT THRESHOLD ADJUSTABLE
GREAT WELD OR SPLICE DETECTOR |
|
Dual
Probe - Double
Metal Sheet Detector
We
call it a Double Metal Sheet Detector
but it is much more
- Separate
adjustments for over & under thresholdAdjust
reject thresholds in 1% increments up
to 99%.
- Detects
Over and Under thickness from Nominal.
- Separate
outputs for Over and Under rejects
- Outputs
indicate Nominal, Over, Under and Nothing
present
- Automatic
calibration eliminate setup time and
optimize settings
- Self
diagnostic messages quickly isolate
system problems, errors and failures
- Automatic
frequency and gain settings provide
simple, quick and accurate startup
- Operating
Power 90 - 240 Volts AC @ 50-60 Hz.
- Compact
Size, (210 mm x 170 mm x 50 mm) to fit
in tight spaces
- Quick
connect terminals for fast replacement
and to reduce downtime
- Latched
or momentary output option
|

Model
DS1510

The
bottom probe, of this
dual probe assembly, is
not shown in this picture.
|
|
|
|
The
Model DS1510 is an easy to operate dual
probe metal thickness detector. Variations
in thickness as small as 1% are detectable.
Control outputs are available for Over,
Under, Normal thickness and Nothing present.
Up to two separate thickness values can
be stored and recalled later through a
remote switch. Ferrous and nonferrous
metals over a range of .05 mm to 8 mm
(.002” to .300”) may be monitored with
Prime’s sensing probes.
Calibration
is simple. Place a metal sheet between
the probe assembly and push the calibrate
button. Add another sheet between the
assembly and push the button again. The
second sheet does not have to be the same
thickness. Repeat both steps for up to
ten separate sheet sizes. After calibration,
the detector sets it’s reject threshold
to 50% between the first and second thickness.
Even the 50% default reject threshold
setting is manually adjustable by holding
the calibrate button in for 3 seconds.
|
The
display prompts either OT (over thickness)
or UT (under thickness). Releasing and
pushing the button again advances the
tolerance value over a range of 1 to 99%.
As a double metal detector the Model DS1510
can discriminate single, double, and no-metal
conditions.
As
a coil thickness or weld splice monitor
it can detect under, over (weld), and
nothing present conditions. The detection
system is not considered a precision thickness
measuring device. However, if metal passing
between it probes is vertically confined
to 5 mm (.200"), it is able to detect
a change of .0250 mm out of .254 mm (.001"
out of .010"), .125 out of 2.5 mm
( 005" out of .100") & .4
mm out of 6 mm (015" out of .250).
The
Nominal Tracking feature adjusts
for acceptable variations in the nominal
thickness.
No
need to worry about loosing values. Nonvolatile
memory stores all settings if power is
lost. Its a great value.
|
|
Specifications:
- Power
Input:
100 to 240 VAC, 50/60 Hz 300 mA operating
load.
- Output:
2 SPDT contact relays Max load: 10 Amps
@ 240 V AC 8 Amps @ 24 V DC ½ HP @ 240
V AC.
- Output
Fail-safe: defaults to reject w/power
off
- Output
Response: adjustable to < .030,
.100, .500, 1 second.
- Probe
Assessment: * determines probe type,
probe separation, nothing present signal
level when powered up or AUXIN input
is closed.
- Thickness
Range: .5 to 2 ounce copper plate.
Up to 100 nonmagnetic stainless steel.
Magnetic SS see DS1500 Family.
- Probe
Models: all probes beginning with
P15, P70, P1000.
- Probe
Separation: 12 mm to 75 mm (.5 to
3”) or more. Max. varies w/(metal, thickness
& probe, separation). Maximum range
is realized with Model P15CS, P70CS,
P1000B.
|
- Calibration:
push-button switch used to change time
interval or manually initiate calibration.
*Two sample calibration. Manually place
two samples between probes, push Cal.
button.
- Enable
Input: enables controlled output
at specific interval.
- Reject
Threshold: variable from 1 to 99%
between two sample calibration. Separate
adjustments for Over and Under.
- LED
Indicators: (1)Green for single,
(3)Amber for Over, Under & Nothing detected.
- Sensor
Operation: eddy Current in metal
impedes signal from transmitter to receiver.
Impedance changes as metal thickness
changes.
- Display
Indication: 2 digit LED, alphanumeric,
.5 inch high. Setup menu, calibration
mode, operating probe signal strength,
fault codes.
|
|
|